Factor library

Emission factors

The sourced factor set behind Prime's inventory — current NGER 2026, NGA 2025, NABERS v2026.2 and IPCC AR6, versioned by reporting year with the source recorded against every factor.

Prime's major likely Scope 1 sources are diesel and petrol company vehicles, diesel generators and plant, LPG where used, natural gas at controlled facilities, refrigerant leakage from Prime-owned or controlled equipment, and potentially SF₆ losses where Prime owns, controls or is responsible for gas-insulated electrical equipment.

Stationary fuels — Scope 1

Source: NGER Determination, Schedule 1 Parts 2 & 3 (current 1 July 2026)

SourceEnergy factorCombined EFPractical Scope 1 factor
Petrol — generator/stationary34.2 GJ/kL67.8 kg CO₂-e/GJ2.3188 kg CO₂-e/L
Diesel — generator/plant38.6 GJ/kL70.22.7097 kg CO₂-e/L
LPG — stationary25.7 GJ/kL60.61.5574 kg CO₂-e/L
Natural gas — pipeline0.0393 GJ/m³51.532.0251 kg CO₂-e/m³
Petroleum lubricating oils*38.8 GJ/kL13.90.5393 kg CO₂-e/L

Lubricating-oil emissions require the applicable consumption/oxidation methodology — do not treat every litre purchased as fully emitted.

Fleet — post-2004 cars & light commercials (Scope 1)

Source: NGER Determination, post-2004 vehicle energy and gas-specific factors (current 1 July 2026)

FuelScope 1 factor
Petrol2.3126 kg CO₂-e/L
Diesel2.7178 kg CO₂-e/L
LPG1.5982 kg CO₂-e/L

Store vehicle type + fuel + model year/emissions standard + litres, rather than one generic diesel factor for everything.

Heavier diesel trucks by emissions standard

Source: NGER Determination (current)

Truck standardScope 1 kg CO₂-e/L
Euro VI or higher2.7294
Euro V2.7294
Euro IV2.7163
Euro III2.7174
Euro I2.7213

SF₆ — gas-insulated switchgear and circuit breakers

Default annual leakage rate

0.89% of gas charge per year

Source: current NGER Measurement Determination (0.0089)

AR6 GWP100 for SF₆

25,200 kg CO₂-e per kg

Source: IPCC AR6 Working Group I, Chapter 7 — 1 kg SF₆ lost = 25.2 t CO₂-e

AASB S2 allows a factor already expressed in CO₂-e to be used as published, but where Prime converts a physical mass of gas to CO₂-e itself, the latest IPCC 100-year GWP (AR6) is required. Maintain an SF₆ register wherever Prime handles gas-filled HV equipment.

Attribution depends on the organisational and control boundary — client-owned equipment does not become Prime Scope 1 merely because Prime worked on it.

Indicative annual refrigerant leakage rates

Source: NGA 2025 workbook

EquipmentIndicative leakage
Transport refrigeration15.7%
Domestic split A/C3.5%
Domestic packaged A/C2.5%
Light vehicle A/C6.7%
Heavy vehicle A/C10.8%

NGA 2025 refrigerant GWPs are AR5. Where Prime converts a raw gas quantity to CO₂-e itself, AASB S2 requires AR6 GWP100. Record refrigerant type + kg charge + actual refill/loss and apply AR6.

© 2026 PrimeGreen — Prime Electrical & Data Services emissions workspace.

© 2025 PrimeGreen. Emissions management platform.